Chemical Feed

Chemical Feed

Problem: MID South Wire Co., Inc. in Nashville, TN uses Yamada Air Operated Double Diaphragm Pumps to supply the feed of sulfuric acid to the centrifuge which is a continuous process and requires as smooth and even a flow rate as possible. The double diaphragm pump was giving good service but, the customer either had to change out the pump for one with continuous flow or find a solution for the pulsating flow.

Deep Well Injection

Deep Well Injection

Problem: Hydroplex HP-350 triplex plunger pump (0.75 gpm at 10,000 psi) for high pressure deep well methanol injection in an oil & gas upstream pumping application. On the discharge side of the pump, the amount of methanol the pump is dosing is metered. Without a dampener to control pulsations and smooth out the flow, the installed flow meters will not give accurate readings. Additionally, when using a triplex pump it is important that all three chambers of the pump stay full of fluid with no voids. Any voids or pockets can cause seals to leak, pump vibration and excess pump noise.